Product Description

FORNEY IDD-II Flame Detection ProbeReliable flame detectors (oil, coal and lignite flames)
FORNEY IDD-II Intelligent Dynamic Flame Detector enables accurate detection and identification of oil flames, coal flames and lignite flames.
The IID-IIU flame detector is used to detect oil flames and coal flames. The IID-IIL flame detector is used to detect lignite flames.
The IDD-II Intelligent Dynamic Flame Detector is used in conjunction with the FORNEY Fire Detection Amplifier DR-6161E, DR-6101, RM-IDD, IDD-IIIA. When the IDD-II flame detector detects the flame, its hardware circuit amplifies the ripple voltage signal generated by the sensing element, and the amplified signal is transmitted to the amplifier via a four-core shielded cable. The amplifier processes the signal and outputs the signal to the burner management system.
The electronic devices of the flame detector are enclosed in a cast aluminum housing. The amplifier periodically performs a self-test to determine if the flame detector is working properly.
Features:
1. Lead sulfide photoelectric sensor:
Infrared and visible light for oil, coal and lignite flames.
2. Dynamic flame detection circuit:
Only produce a dynamic flame signal, without detecting heat radiation.
3. Simple and durable structure:
The circuit board and the sensing element are enclosed in a cast aluminum housing as a replaceable part.
4. Easy installation and maintenance:
Fast electrical and mechanical contact, easy installation and maintenance.
5. FM certification
IDD-II intelligent dynamic flame detector
Product and installation accessories
IID-II has filters (coal and # 6 oil)
IID-IIU no filter (# 2 oil and gas)
IID-IIU no filter (# 2 oil and gas)

 

Nanjing Win Union Automation and Control Technology Co., Ltd.

Sales : Tonny  

TEL: ( 86-25)-52791167   52791168

FAX: ( 86-25)-52791169

Website: http://www.ylue.cn

E-mail:  njxj888@163.com     

Add: Jiangning Shuanglong Avenue No.1222  Nanjing, Jiangsu. China 211100

 

Forney Flame Detector, Forney Flame Detector, Forney Flame Detector, Forney Flame Detector, Forney Flame Detector, Forney Flame Relay, Forney UV Flame Sensor, Forney Processor, Forney Infrared Probe, etc.
The Forney PM-DR-6101E amplifier is a stand-alone intelligent controller consisting of two printed circuit boards (PCBs) with a cover base. One of the PCBs includes a combination of power supplies, relays, and output / input (I / O) interface software. Another PCB includes microprocessors, stabilizers and signal processing electronics. The entire unit can be installed in a separate cabinet. IDD-II infrared filter with filter, IDD-IIU without filter infrared probe, UV-4 probe, DR-6 IDD / UV probe.
D Furnace Flame Detector Uniflame 95 Series
Overview: FORNEY UNIFLAME series flame detectors are based on microprocessor-based flame detectors using solid-state infrared sensors (IR), UV sensors (UV) and dual sensors (IR UV). The detectors are equipped with an internal flame relay and can adjust the ON / OFF threshold, so no remote flame amplifiers are required. The UNIFLAME \ 95 series detector combines the principles and characteristics of the FORNEY DPD Flame Detector to detect the presence or absence of a target flame in a single burner or multiple burner conditions. The UNIFLAME \ 95 series detector detects the modulation amplitude of the target flame (ie, the flicker characteristic of the flame). In the setting procedure of the detector, the modulation frequency characteristic which produces the optimum flame ON / OFF resolution is selected. And can be manually adjusted or automatically adjusted to select the appropriate modulation frequency and detector gain. UNIFLAME \ 95 series detector with automatic programming (self-learning) function; 21 kinds of flame flashing frequency selection; 4 optional programming files to store the set value; also increased by using FORNEY WINDOWS95 / 98 / NT based on the user application Software remote communication function. All UNIFLAME \ 95 detectors require 24VDC power supply, with 12-pin quick connector, electronic self-test function (no need for mechanical shutter). The detector is equipped with an 8-digit alphanumeric LED display and 4 buttons for easy viewing of operating parameters and selection settings.
application:
IR type: includes an infrared flame sensor, this sensor is suitable for oil and coal fuel situation. UV type: includes an ultraviolet flame sensor, this sensor is suitable for gas fuel and light oil fuel situation.
DS type: (dual sensor) including the above infrared and ultraviolet two kinds of flame sensors, this sensor is suitable for multi-fuel situation.
Uniflame series with the installation of accessories: mechanical accessories plate mounted flange (must) regardless of the detector is a straight-like installation or fiber-type installation, you need to use the disk flange, plate flange flange for the external "1" NPT internal thread, Material is hard aluminum. Universal joint (straight-type optional) ?? detector universal joint, is installed in the detector after the detector used to adjust the angle of observation. Insulation tube (straight-type must be) separated The heat pipe is to prevent the heat from being transferred from the heat of the observation tube to the detector, while the detector is electrically insulated from the earth. The corresponding observation tube is ordered with the mounting flange. Quartz window (straight-sight optional) Quartz window, Need to be sealed or connected to use, the quartz window to block the pressure of the furnace, hot gas and coal ash, so that it can not be close to the detector or contaminated lenses. Specifications are 1 inch US standard tapered thread. A fiber optic assembly, a fiber wall assembly, an optical fiber assembly, an optical fiber assembly, an optical fiber assembly, an optical fiber assembly, an optical fiber assembly, an optical fiber assembly, an optical fiber assembly, an optical fiber assembly, In the boiler, the use of fiber components can be flame "flashing" signal through the optical fiber transmission to the furnace, easy to monitor the detector. Electrical accessories detector cable FORNEY provide UNIFLAME \ 95 series detector dedicated 12-core foil shielded cable . This cable consists of 6 # 18 AWG and 4 # 22AWG wires, plus a pair of # 22AWG twisted pair. The cable jacket is a treated polyolefin material (flame retardant, low, zero halogen) maximum diameter of 0.43 " 10.9 mm). Each detector has a maximum cable of up to 1000 feet. This adhesive cable requires the quick connector described below. Fast installation UNIFLAME \ 95 series detector factory comes with 12-pin cable male connector, FORNEY can provide matching cable connector, easy on-site installation. Refer to the aviation plug accessories manual. Cable with adapter fitting FORNEY offers prefabricated 12-core cable, length can be set, factory with female connector. The attachment ranges from 10 feet (3m) to 300 feet (91m). Junction Box Assemblies If remote communication is required, the distance between the UNIFLAME detector and the control room is more than 200 feet (61M), then each detector requires a junction box. In the junction box, the two communication lines must be connected with the 12-core cable, in the loop, in a multi-point series (daisy chain) connected to each detector, and finally to the computer.
FORNEY Junction Box components, ranging from 3 to 30 feet (0.9 to 9.1 meters), provide a convenient wiring. At one end of the junction box there is a quick connector to connect to the UNIFLAME detector. The FORNEY 12-core cable is shipped with a quick connector and a flexible cable that can be connected to another terminal in the junction box. The terminal can be connected to the 14AWG wire, which can be quickly and securely connected with a push-in clamp connector. Through the junction box, the installer can connect all the wiring, but the FORNEY 12-core cable to the burner management system to connect the two lines are not connected. The two communication lines from the detector must be connected to the upper and lower junction boxes, and finally through the two-core communication cable to reach the computer. 24VDC Power Supply FORNEY provides 24VDC power for the 95 Series Flame Detector.